| Brand & Model | Energy | Type | Dimensions | Cost (€) | ||
|---|---|---|---|---|---|---|
![]() | Liebherr SFTvh 1501 | Energy (kWh/year): 187 Efficiency index (%): 68,3 | Laboratory freezers Forced-air | Total net volume (l): 59 | Electricity in 15 years: 841 |
Energy (kWh/24h):
0,51
Refrigerant:
R600a
Temperature range (°C):
-35 … -9 °C
Ambient temperature (°C):
+10 °C to 35 °C
Height (mm):
819
Width (mm):
597
Depth (mm):
605
|
![]() | Vestfrost R-90i Glass | Energy (kWh/year): 123 Efficiency index (%): 43,9 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 76 | Electricity in 15 years: 552 |
Energy (kWh/24h):
0,34
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
672
Width (mm):
595
Depth (mm):
642
|
![]() | Vestfrost R-90i | Energy (kWh/year): 106 Efficiency index (%): 37,9 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 76 | Electricity in 15 years: 476 |
Energy (kWh/24h):
0,29
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
672
Width (mm):
595
Depth (mm):
642
|
![]() | Liebherr HMTvh 1501 | Energy (kWh/year): 111 Efficiency index (%): 38,4 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 102 | Electricity in 15 years: 499 |
Energy (kWh/24h):
0,30
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
Height (mm):
819
Width (mm):
597
Depth (mm):
605
|
![]() | Liebherr HMTvh 1511 | Energy (kWh/year): 187 Efficiency index (%): 64,6 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 102 | Electricity in 15 years: 841 |
Energy (kWh/24h):
0,51
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
Height (mm):
819
Width (mm):
597
Depth (mm):
605
|
![]() | Liebherr SRTvh 1511 | Energy (kWh/year): 187 Efficiency index (%): 64,6 | Laboratory fridges Forced-air | Total net volume (l): 102 | Electricity in 15 years: 841 |
Energy (kWh/24h):
0,51
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
Height (mm):
819
Width (mm):
597
Depth (mm):
605
|
![]() | Liebherr SRTvh 1501 | Energy (kWh/year): 111 Efficiency index (%): 38,4 | Laboratory fridges Forced-air | Total net volume (l): 102 | Electricity in 15 years: 499 |
Energy (kWh/24h):
0,30
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
Height (mm):
819
Width (mm):
597
Depth (mm):
605
|
![]() | Vestfrost R-138i Glass | Energy (kWh/year): 158 Efficiency index (%): 53,7 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 117 | Electricity in 15 years: 711 |
Energy (kWh/24h):
0,43
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
825
Width (mm):
595
Depth (mm):
642
|
![]() | Vestfrost R-138i | Energy (kWh/year): 122 Efficiency index (%): 41,4 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 117 | Electricity in 15 years: 549 |
Energy (kWh/24h):
0,33
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
825
Width (mm):
595
Depth (mm):
642
|
![]() | Liebherr SFFvh 4001 001 20 Series products: SFFvh 4001: 006 20, 147 20 | Energy (kWh/year): 427 Efficiency index (%): 81,2 | Laboratory freezers Forced-air | Total net volume (l): 174 | Electricity in 15 years: 1'922 |
Energy (kWh/24h):
1,17
Refrigerant:
R600a
Temperature range (°C):
-35 … -9 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Vestfrost R-281 Essential | Energy (kWh/year): 301 Efficiency index (%): 93,5 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 193 | Electricity in 15 years: 1'357 |
Energy (kWh/24h):
0,83
Refrigerant:
R600a
Temperature range (°C):
+2 … +10 °C
Ambient temperature (°C):
32 °C
Height (mm):
1'560
Width (mm):
595
Depth (mm):
595
|
![]() | Liebherr SCFvh 4002 001 20 Series products: SCFvh 4002 006 20 | Energy (kWh/year): 474 Efficiency index (%): 79,3 | Storage refrigerator-freezers Forced-air | Total net volume (l): 264 | Electricity in 15 years: 2'135 |
Energy (kWh/24h):
1,30
Refrigerant:
R600a
Temperature range (°C):
-35 … -9 °C / +3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SCFvh 4032 001 20 | Energy (kWh/year): 562 Efficiency index (%): 94,0 | Storage refrigerator-freezers Forced-air | Total net volume (l): 264 | Electricity in 15 years: 2'531 |
Energy (kWh/24h):
1,54
Refrigerant:
R600a
Temperature range (°C):
-35 … -9 °C / +3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr HMFvh 4001 001 20 Series products: HMFvh 4001: 006 20, H63 20 | Energy (kWh/year): 168 Efficiency index (%): 46,7 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 295 | Electricity in 15 years: 756 |
Energy (kWh/24h):
0,46
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr HMFvh 4011 001 20 Series products: HMFvh 4011: 006 20, 147 20, H63 20 | Energy (kWh/year): 270 Efficiency index (%): 75,1 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 297 | Electricity in 15 years: 1'217 |
Energy (kWh/24h):
0,74
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRFvh 4011 001 20 | Energy (kWh/year): 270 Efficiency index (%): 75,1 | Laboratory fridges Forced-air | Total net volume (l): 297 | Electricity in 15 years: 1'217 |
Energy (kWh/24h):
0,74
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRFvh 4001 001 20 | Energy (kWh/year): 168 Efficiency index (%): 46,6 | Laboratory fridges Forced-air | Total net volume (l): 298 | Electricity in 15 years: 756 |
Energy (kWh/24h):
0,46
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Vestfrost R-427i | Energy (kWh/year): 160 Efficiency index (%): 41,7 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 361 | Electricity in 15 years: 719 |
Energy (kWh/24h):
0,44
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
2'002
Width (mm):
595
Depth (mm):
642
|
![]() | Vestfrost R-427i Glass | Energy (kWh/year): 182 Efficiency index (%): 47,5 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 361 | Electricity in 15 years: 820 |
Energy (kWh/24h):
0,50
Refrigerant:
R600a
Temperature range (°C):
0 … +20 °C
Ambient temperature (°C):
35 °C
Height (mm):
2'002
Width (mm):
595
Depth (mm):
642
|
![]() | Liebherr HMFvh 5511 001 20 Series products: HMFvh 5011: 147 20, H63 20 | Energy (kWh/year): 290 Efficiency index (%): 70,6 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 435 | Electricity in 15 years: 1'304 |
Energy (kWh/24h):
0,79
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr HMFvh 5501 001 20 Series products: HMFvh 5001: H63 20 | Energy (kWh/year): 182 Efficiency index (%): 44,2 | Medical & pharmaceutical fridges Forced-air | Total net volume (l): 436 | Electricity in 15 years: 818 |
Energy (kWh/24h):
0,50
Refrigerant:
R600a
Temperature range (°C):
+5 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRFvh 5511 001 20 | Energy (kWh/year): 290 Efficiency index (%): 70,3 | Laboratory fridges Forced-air | Total net volume (l): 440 | Electricity in 15 years: 1'304 |
Energy (kWh/24h):
0,79
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRFvh 5501 001 20 | Energy (kWh/year): 182 Efficiency index (%): 44,0 | Laboratory fridges Forced-air | Total net volume (l): 441 | Electricity in 15 years: 818 |
Energy (kWh/24h):
0,50
Refrigerant:
R600a
Temperature range (°C):
+3 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRPvh 6501 001 20 | Energy (kWh/year): 178 Efficiency index (%): 41,6 | Laboratory fridges Forced-air | Total net volume (l): 480 | Electricity in 15 years: 800 |
Energy (kWh/24h):
0,49
Refrigerant:
R600a
Temperature range (°C):
-2 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRPvh 6511 001 20 | Energy (kWh/year): 310 Efficiency index (%): 72,6 | Laboratory fridges Forced-air | Total net volume (l): 480 | Electricity in 15 years: 1'396 |
Energy (kWh/24h):
0,85
Refrigerant:
R600a
Temperature range (°C):
0 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SFPvh 6501 001 40 | Energy (kWh/year): 1'194 Efficiency index (%): 99,8 | Laboratory freezers Forced-air | Total net volume (l): 480 | Electricity in 15 years: 5'373 |
Energy (kWh/24h):
3,27
Refrigerant:
R290
Temperature range (°C):
-35 … -9 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRPvh 8401 001 20 | Energy (kWh/year): 218 Efficiency index (%): 42,8 | Laboratory fridges Forced-air | Total net volume (l): 702 | Electricity in 15 years: 979 |
Energy (kWh/24h):
0,60
Refrigerant:
R600a
Temperature range (°C):
-2 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRPvh 8411 001 20 | Energy (kWh/year): 367 Efficiency index (%): 72,3 | Laboratory fridges Forced-air | Total net volume (l): 702 | Electricity in 15 years: 1'652 |
Energy (kWh/24h):
1,01
Refrigerant:
R600a
Temperature range (°C):
0 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SFPvh 8401 001 40 | Energy (kWh/year): 1'279 Efficiency index (%): 76,1 | Laboratory freezers Forced-air | Total net volume (l): 702 | Electricity in 15 years: 5'757 |
Energy (kWh/24h):
3,50
Refrigerant:
R290
Temperature range (°C):
-35 … -9 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SRPvh 1402 001 20 | Energy (kWh/year): 448 Efficiency index (%): 68,9 | Laboratory fridges Forced-air | Total net volume (l): 1'091 | Electricity in 15 years: 2'015 |
Energy (kWh/24h):
1,23
Refrigerant:
R600a
Temperature range (°C):
-2 … +16 °C
Ambient temperature (°C):
+10 °C to 35 °C
|
![]() | Liebherr SFPvh 1402 001 40 | Energy (kWh/year): 2'143 Efficiency index (%): 84,6 | Laboratory freezers Forced-air | Total net volume (l): 1'091 | Electricity in 15 years: 9'641 |
Energy (kWh/24h):
5,87
Refrigerant:
R290
Temperature range (°C):
-35 … -9 °C
Ambient temperature (°C):
+10 °C to 35 °C
|