horizontalcompare
Brand
Model
Other models
Electricity costs
(€ in 8 years)
Total display area (m2)
Net volume (liters)
Storage temperature (°C)
Temperature class
Climate class
Draft energy index
Energy (kWh/year)
Refrigerant
Cooling
Countries available
Liebherr STs 1072 SGTs 1072 2712 1.68 740 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 22.5 1'695 R290 Static EU
Carrier Multinor 1530 G   1928 1.03 242 –18...–23 3H 3 (25°C, 60% RH) 23.1 1'205 R290 Forced-air EU
Liebherr STm 1172 SGTm 1172 2851 1.68 816 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 23.6 1'782 R290 Static EU
Liebherr STs 872 SGTs 872 2594 1.4 601 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 24.8 1'621 R290 Static EU
Liebherr STm 972 SGTm 972 2627 1.4 664 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 25.1 1'642 R290 Static EU
Liebherr STEs 772 SGTEs 772 2366 1.19 497 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 25.6 1'479 R290 Static EU
Liebherr STEm 872 SGTEm 872 2398 1.19 550 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 25.9 1'499 R290 Static EU
Novum 601L (no lighting) 610L (no lighting), 601L (with LED), 610L (with LED) 1862 0.82 484 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 26.1 1'164 R290 Static EU
Liebherr ST 1122 SGT 1122, STE 1122 3117 1.41 540 –19...–21/ +2...+4 L1 (-15...-18°C) 3 (25°C, 60% RH) 29.7 1'948 R290 Static/ Forced-air/ Forced-air EU
Liebherr ST 1322 SGT 1322 3688 1.71 669 –19...–21/ +2...+4 L1 (-15...-18°C) 3 (25°C, 60% RH) 30.1 2'305 R290 Static/ Forced-air/ Forced-air EU
ArcaBoa Dupla 2.2 DR Dupla 2.2 R 5549 2.65 1255 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 31.4 3'468 R290 Static EU
ArcaBoa Super 2.5 DR Super 2.5 R 4205 1.9 750 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 31.6 2'628 R290 Static EU
ArcaBoa Super 2 DR Super 2 R 3504 1.49 580 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 31.9 2'190 R290 Static EU
Novum Grand Cayman 1008 SC (no lighting) Grand Cayman 1008 SC-LED, Grand Cayman 1008 EOA (no lighting), Grand Cayman 1008 EOA-LED 3504 1.48 830 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 32.1 2'190 R290 Forced-air EU
AHT Paris ECO 250 (U) ... Paris ECO ... : 250 (-), 210 (U), 210 (-) 3766 1.54 770 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C)/S/S 3 (25°C, 60% RH) 33.4 2'354 R290 Static/ Forced-air/ Forced-air EU
Novum Line 601FF (no lighting) Line 601FFL, Line 610FF (no lighting), Line 610FFL 2453 0.8 468 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 34.9 1'533 R290 Forced-air EU
AHT Sydney XL 213 (-) ... Sydney XL ... : 213 (U), 223 (U), 223 (-), 230 (-), 250 (U), 175 XL (U), 175 XL (-), 210 XL (U), 210 XL (-), 250 XL (U), 250 XL (-) 3738 1.39 677 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 35.9 2'336 R290 Static EU
ArcaBoa Dupla Topo DR Dupla Topo R 2294 0.65 334 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 37.2 1'434 R290 Static EU
AHT Paris ECO 185 (U) ... Paris ECO ... : 185 (-), 180 (U), 180 (-), 175 (U), 175 (-), 145 (U), 145 (-) 3182 1.04 529 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C)/S/S 3 (25°C, 60% RH) 37.9 1'989 R290 Static/ Forced-air/ Forced-air EU
AHT Macao 210 (U) ... Macao 210 (-) ... 3797 1.26 338 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C) 3 (25°C, 60% RH) 39.3 2'373 R290 Static/ Forced-air/ Forced-air EU
AHT Athen XL ECO 175 (-) ...   3797 1.25 709 –18...–23 L1 (-15...-18°C) 3 (25°C, 60% RH) 39.5 2'373 R290 Static EU
AHT Athen XL ECO 250 (U) ... Athen XL ECO... : 250 (-), 210 (U), 210 (-), 207 (U), 207 (-) 5203 1.86 1025 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C) 3 (25°C, 60% RH) 39.7 3'252 R290 Static/ Forced-air/ Forced-air EU
AHT Miami ECO 185 (U) L ... Miami ECO ...: 185 (-), 210 (U), 210 (-), 250 (U) L, 250 (-) 4038 1.26 547 -18...-23 L1 (-15...-18°C) 3 (25°C, 60% RH) 41.8 2'524 R290 Static/ Forced-air/ Forced-air EU
JBG 2 Pamir Island / WNPA-1530-01 3L1-I-R290-CSS-I4E with lighting 3563 1.02 223 –21...–25 L1 (-15...-18°C) 3 (25°C, 60% RH) 43.0 2'227 R290 Forced-air EU
Novum Aran 806 SC   4594 1.14 742 –18...–25 L1 (-15...-18°C) 3 (25°C, 60% RH) 44.7 2'871 R290 Forced-air EU
AHT Manhattan ECO 175 (U) ... Manhattan ECO 175 (-) ... 4016 1.08 605 –18...–23/ 0...+2/ +3...+15 L2 (-12...-18°C) 3 (25°C, 60% RH) 46.5 2'510 R290 Static/ Forced-air/ Forced-air EU
AHT Macao 145 (U) ... Macao 145 (-) ... 3387 0.84 217 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C) 3 (25°C, 60% RH) 46.7 2'117 R290 Static/ Forced-air/ Forced-air EU
AHT Ibiza 210 (U) ... Ibiza 210 (-) ... 4789 1.3 561 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C) 3 (25°C, 60% RH) 48.4 2'993 R290 Static/ Forced-air/ Forced-air EU
AHT Ibiza 145 (U) ... Ibiza 145 (-) ... 3680 0.86 342 –18...–23/ 0...+2/ +3...+15 L1 (-15...-18°C) 3 (25°C, 60% RH) 49.9 2'300 R290 Static/ Forced-air/ Forced-air EU
Inefficient model     6717 1.56 893 -18...-25 L1 (-15...-18°C) 3 (25°C, 60% RH) 59.0 4'198 R507 Static EU