Adande HCS R2 Side Engine HCR R2 Rear Engine 382 86 0...+15 5 - heavy-duty A+ 11.9 239 R600a Forced-air 1100 x 700 x 494 EU
Gram COMPACT K 210 RG COMPACT K 210 LG 515 76 +2...+12 4 A 16.2 322 R600a Forced-air 595 x 640 x 830 EU
Electrolux Ecostore Premium HP 710001 (EH2HBAA)   730 198 -2...+10 5 - heavy-duty A 19.87 456 R290 Forced-air 1340 x 700 x 900 EU
Alpeninox HP Premium 712001 (AH2HBAA)   730 198 -2...+10 5 - heavy-duty A 19.87 456 R290 Forced-air 1340 x 700 x 900 EU
Mercatus L2-1795   834 283 -2...+8 4 A 20.7 521 R290 Forced-air 1795 x 700 x 970 EU
Desmon PTGM4   1051 530 -2...+8 4 A 20.9 657 R290 Forced-air 2430 x 700 x 850 IT, FR, ES, GR, UK, DE, CH
Alpeninox HP Premium 712027 (AH3HBAAA)   896 310 -2...+10 5 - heavy-duty A 21.69 560 R290 Forced-air 1795 x 700 x 900 EU
Electrolux Ecostore Premium HP 710028 (EH3HBAAA)   896 310 -2...+10 5 - heavy-duty A 21.69 560 R290 Forced-air 1795 x 700 x 900 EU
Coreco HMRG-200   915 309 -2...+8 5 - heavy-duty A 22.17 572 R290 Forced-air 1800 x 700 x 850 EU
Desmon PTGM3   994 376 -2...+8 4 A 22.6 621 R290 Forced-air 1945 x 700 x 850 IT, FR, ES, GR, UK, DE, CH
Coreco HMRG-150   869 187 -2...+8 5 - heavy-duty A 23.93 543 R290 Forced-air 1350 x 700 x 850 EU
Inefficient model     1440 150 +2...+12 4 C 41.4 900 R134a Forced-air 600 x 600 x 830 EU