verticalcompare
Brand
Model
Other models
Electricity costs
(€ in 8 years)
Net volume (liters)
Storage temperature (°C)
Climate class
Energy efficiency class
Energy Efficiency Index
Energy (kWh/year)
Refrigerant
Cooling
Dimensions W/D/H (mm)
Countries available
20/02/2019
Liebherr Liebherr Adande Inefficient model Adande Adande Gram
GGU 1500 GGU 1400 VCC R2   VLS R2 VCS R2 Side Engine COMPACT F 210 LG
GGU 1550         VCR R2 Rear Engine, VCM R2 COMPACT F 210 RG
730 933 1525 1867 1250 1218 1448
107 101 68.8 100 64.8 86.2 76
-26...-9 -32...-15 -22...+15 -22...-5 -22...+15 -22...+15 -22...-5
4   4 4 5 - heavy-duty 5 - heavy-duty 4
(A) (A) B C B B B
15.2 19.6 34.2 39.4 28.3 26.4 32
456 583 953 1'167 781 761 905
R600a R600a R600a R134a R600a R600a R600a
Static Static Forced-air Forced-air Forced-air Forced-air Forced-air
600 x 615 x 830 600 x 615 x 830 450 x 800 x 845 600 x 600 x 830 1100 x 700 x 436 1100 x 700 x 494 595 x 640 x 830
AT, BG, CH, DE EU ∖ AT EU EU EU EU EU